Python IVI can use Python VXI-11, Python USBTMC, pySerial and linux-gpib to connect to instruments. The implementation of the initialize method takes a VISA resource string and attempts to connect to an instrument. For more information on this or other products and their availability, please contact your local JDSU account manager or JDSU directly at 1-800-498-JDSU (5378) in North America and +800-5378-JDSU worldwide or via e-mail at.
- Current page: 1 of 19
sfp-gi2lktd5dca Summary of contents
Page 1
... Ethernet and 1G Fibre Channel also compatible to Fast Ethernet, SONET OC-3 and OC-12, and SDH STM-1 and STM-4 standards. The SFP optical transceiver integrates the receive and transmit path on one module. In the transmit side, the serial data stream is passed to a laser driver. The laser driv- ers biases and modulates an uncooled DML (direct modulated laser), enabling data transmission over single-mode fiber through an industry-standard LC connector ...
Page 2
... INF-8074i Rev. 1.0. A block diagram of the JDSU SFP optical transceiver is shown in Figure 1 below. The JDSU SFP optical transceiver does not need Rate Select to operate at the desig- nated line rate. It has several low-speed interface connections including a 2-wire serial interface. These connections also include: transceiver presence (Mod_Def(0)), trans- mitter fault (TX_FAULT), transmitter disable (TX_DIS), and receive loss (RX_LOS) ...
Page 3
... TD+ RX_LOS TX_FAULT TX_DIS Figure 1 SFP OPTICAL TRANSCEIVER—OC-48 AND OC-12 FOR UP TO 80-KM REACH AND GIGABIT ETHERNET FOR UP TO 120-KM REACH Low-speed Signaling Low-speed signaling is based on low-voltage TTL (LVTTL) operating at a nominal voltage of 3.3 V. MOD_DEF(1) / MOD_DEF(2): Two-wire serial interface clock and data line. ...
Jds Uniphase Port Devices Driver Download 32-bit
Page 4
... REACH AND GIGABIT ETHERNET FOR UP TO 120-KM REACH Section 2 Application Schematics Power supply filtering is recommended for the JDSU SFP optical transceiver. To limit wide-band noise power, the host system and module shall each meet a maxi- mum of 2 percent peak-to-peak noise when measured with a 1 MHz low-pass filter. In addition, the host system and the module shall each meet a maximum of 3 percent peak-to-peak noise when measured with a filter from 1 – ...
Page 5
... Pin Function Definitions Figure 3 SFP OPTICAL TRANSCEIVER—OC-48 AND OC-12 FOR UP TO 80-KM REACH AND GIGABIT ETHERNET FOR UP TO 120-KM REACH Section 3 Specifications Technical specifications related to the JDSU SFP optical transceiver include: Section 3.1 Pin Function Definitions Section 3.2 Absolute Maximum Ratings Section 3.3 Operating Conditions Section 3 ...
Page 6
... Absolute maximum ratings represent the damage threshold of the device. Damage may occur if the device is operated above the limits stated here except for brief excursions. Performance is not guaranteed and reliability is not implied for operation at any condition outside the recommended operating limits. SFP OPTICAL TRANSCEIVER—OC-48 AND OC-12 FOR UP TO 80-KM REACH AND GIGABIT ETHERNET FOR UP TO 120-KM REACH ...
Page 7
... Operating Conditions Part Number Gigabit Ethernet SFP-PL1LKTD3DCA SFP-PL2LKTD5DCA SFP-PE2LKTD5DCA SFP-GI1LKTD3DCA 40 km SFP-GS2LKTD5DCA 40 km SFP-GI2LKTD5DCA 80 km SFP-GL1LKTD3DCA 60 km SFP-GL2LKTD5DCA 120 km SFP-MI1LKTD3DCA SFP-MI2LKTD5DCA SFP-ML1LCTD3DCA SFP-ML1LKTD3DCA SFP-ML2LCTD5DCA SFP-ML2LKTD5DCA 3.4 Electrical Characteristics Parameter Symbol Minimum Supply currents and voltages Supply voltage V 3.13 CC Supply current I CC Power dissipation ...
Page 8
... The DWDM SFP optical transceiver incorporates a SFP compliant two-wire management interface, which is used for serial ID, digital diagnostics, and certain control functions modeled on the DWDM SFP MSA Rev. 1.0 specification modified to accommodate a single two-wire interface address. Details of the protocol and interface are explicitly described in the MSA. ...
Page 9
... Measured with PRBS 2 – 1 pattern; with 1000 waveforms. 3. Measured with worst ER; BER < 10 -12 ; PRBS 2 23 –1 pattern. SFP OPTICAL TRANSCEIVER—OC-48 AND OC-12 FOR UP TO 80-KM REACH AND GIGABIT ETHERNET FOR UP TO 120-KM REACH 2-wire address 1010001X (A2h) 0 Alarm and Warning Thresholds (56 bytes) 55 ...
Page 10
... Tested with PRBS 2 23 –1 pattern Measured with PRBS 2 – 1 pattern; with 1000 waveforms. - Measured with worst ER; BER < PRBS 2 –1 pattern. SFP OPTICAL TRANSCEIVER—OC-48 AND OC-12 FOR UP TO 80-KM REACH AND GIGABIT ETHERNET FOR UP TO 120-KM REACH Symbol Minimum Typical P -3.0 avg λ ...
Page 11
... Tested with PRBS 2 –1 pattern Measured with PRBS 2 – 1 pattern; with 1000 waveforms. - Measured with worst ER; BER < PRBS 2 –1 pattern. SFP OPTICAL TRANSCEIVER—OC-48 AND OC-12 FOR UP TO 80-KM REACH AND GIGABIT ETHERNET FOR UP TO 120-KM REACH Symbol Minimum Typical P -5.0 avg ER 9 λ ...
Page 12
... Tested with PRBS 2 –1 pattern Measured with PRBS 2 – 1 pattern; with 1000 waveforms. - Measured with worst ER; BER < PRBS 2 –1 pattern. SFP OPTICAL TRANSCEIVER—OC-48 AND OC-12 FOR UP TO 80-KM REACH AND GIGABIT ETHERNET FOR UP TO 120-KM REACH Symbol Minimum Typical P 0.0 2.0 avg DT ...
Jds Uniphase Port Devices Driver Download Windows 10
Page 13
... Tested with PRBS 2 –1 pattern Measured with PRBS 2 – 1 pattern; with 1000 waveforms. - Measured with worst ER; BER < PRBS 2 –1 pattern. SFP OPTICAL TRANSCEIVER—OC-48 AND OC-12 FOR UP TO 80-KM REACH AND GIGABIT ETHERNET FOR UP TO 120-KM REACH Symbol Minimum Typical P 0.0 avg ...
Page 14
... Tested with PRBS 2 23 –1 pattern. 2. Measured with PRBS 2 23 – 1 pattern; with 1000 waveforms. 3. Measured with worst ER; BER < 10 -12 ; PRBS pattern. SFP OPTICAL TRANSCEIVER—OC-48 AND OC-12 FOR UP TO 80-KM REACH AND GIGABIT ETHERNET FOR UP TO 120-KM REACH Symbol Minimum Typical P -5.0 avg 8.2 λ ...
Page 15
... Regulatory Compliance The JDSU SFP optical transceiver is lead-free and RoHS 6/6-compliant per Directive 2002/95/EC of the European Parliament and of the Council of 27 January 2003 on the restriction of the use of certain hazardous substances in electrical and electronic equipment. The SFP optical transceiver complies with international electromagnetic compatibility (EMC) and international safety requirements and standards ...
Page 16
... Component safety RoHS-compliance Laser eye safety Electromagnetic Compatibility Electromagnetic emissions Electromagnetic immunity ESD immunity Radiated immunity SFP OPTICAL TRANSCEIVER—OC-48 AND OC-12 FOR UP TO 80-KM REACH AND GIGABIT ETHERNET FOR UP TO 120-KM REACH Test Method Performance UL 60950 TUV Certificate UL94-V0 TUV Certificate EN 60950 ...
Page 17
... Module Outline 1.8 ± 0.1 9.1 ± 0.1 0.9 ± 0.1 13.7 ± 0.1 3.22 Connectors Fiber The SFP module has a duplex LC receptacle connector. Electrical The electrical connector is the 20-way, two-row PCB edge connector. SFP OPTICAL TRANSCEIVER—OC-48 AND OC-12 FOR UP TO 80-KM REACH AND GIGABIT ETHERNET FOR UP TO 120-KM REACH 55.0±0.25 2.6 ± 0.1 45.0 ± ...
Jds Uniphase Port Devices Driver Download 64-bit
Page 18
... MEK, methylene chloride, methylene dichloride, phenol, N-methylpyrolldone). This product is not designed for aqueous wash. Housing The JDSU SFP optical transceiver housing is made from die-cast zinc and stainless steel sheet metal. 4.2 ESD Discharge (ESD) Handling Normal ESD precautions are required during the handling of this module. This transceiver is shipped in ESD protective packaging ...
Page 19
... SFP transceiver GbE 1310 industrial temperature SFP-GL1LKTD3DCA SFP transceiver GbE 1310 industrial temperature SFP-GS2LKTD5DCA SFP transceiver GbE 1550 industrial temperature SFP-GI2LKTD5DCA SFP transceiver GbE 1550 industrial temperature SFP-GL2LKTD5DCA SFP transceiver GbE 1550 nm 120 km industrial temperature SFP-MI1LKTD3DCA SFP transceiver OC48 IR-1 1310 industrial temperature ...
Related keywords
- sfp-gi2lktd5dca datasheet
- sfp-gi2lktd5dca data sheet
- sfp-gi2lktd5dca pdf datasheet
- sfp-gi2lktd5dca component
- sfp-gi2lktd5dca part
- sfp-gi2lktd5dca distributor
- sfp-gi2lktd5dca RoHS
- sfp-gi2lktd5dca datasheet download
Additionally, the 4900 series takes advantage of the existing JDSU global infrastructure to combine highly reliable design with cost-effective manufacturing.
For complete specifications please refer to the pdf data sheet below. To request a quotation for this device, please utilize the Request Price Quote link above.
Download Full PDF Data Sheet:
Any user of this site is welcome to upload PDF data sheets for products they use and recommend. One of the ways we help our community of laser scientists & engineers find the best products for their projects is by hosting a free open-index product database.
Jds Uniphase Port Devices Driver Download Mac
All manufacturers / suppliers are welcome to upload their data sheets free of charge. Our software posts the PDF data sheet into the correct category. Manufacturers get increased exposure. Site users contact them directly for price / delivery information. To post your data sheet(s), go to our upload PDF data sheets portal.
Jds Uniphase Port Devices Driver Download Windows 7
Customers Also Considered: